- LCD Modules[1]
- Other Electrical Equipment[6]
- Solar Energy Systems[3]
- Electricity Generation[3]
- Uninterrupted Power Supply (UPS)[4]
- Inverters & Converters[6]
- Other Electronic Components[1]
- Other Motor Accessories[1]
- Other PCB & PCBA[1]
- Keypads & Keyboards[1]
- Other Power Supplies[2]
- Filters[1]
- Integrated Circuits[1]
- Contact Person : Mr. Wang Jian
- Company Name : Shenzhen Invt Electric Co., Ltd.
- Tel : 86-755-86312834
- Fax : 86-755-86312970
- Address : Guangdong,Shenzhen,No.4 Building, Gaofa Industrial Park, Longjing, Nanshan District, Shenzhen, ChinaNo.4 Building, Gaofa Industrial Park, Longjing, Nanshan District, Shenzhen, China
- Country/Region : China
- Zip : 518057
Related Product Searches:Offline UPS Bu Series 400VA~1200VA,High Quality,Offline Ups, Line Interactive Ups,Bu Series
Description
MODEL | BU400VA | BU500VA | BU650VA | BU750VA | BU800VA | BU1000VA | BU1200VA | |
CAPACITY | VA/W | 240W | 300W | 390W | 450W | 480W | 600W | 720W |
Input | Voltage | 110Vac/220Vac/230Vac/240Vac | ||||||
Voltage range | 75-145v OR 145-280V | |||||||
Frequency | 50Hz/60Hz | |||||||
Output | Frequency | 50Hz /60Hz | ||||||
Voltage | 110Vac/220Vac/230Vac/240Vac | |||||||
Transfer time | < 10ms including direction time | |||||||
Wave form | Sine wave under mains supply, square wave under battery operation | |||||||
Battery | BAttery Type and Number | 12v4.5ah*1pc | 12v7ah*1pc | 12v9ah*1pc | 12v7ah*2pcs | 12v9ah*2pcs | ||
| Backup Time(at a pc load with 17" monitor) | 5-7 minutes | 8-15 minutes | 15-28minutes | 25-40minutes | 30-50 minutes | ||
| Recharge Time | 10 hours | ||||||
Transfer Time | typical | < 10MS | ||||||
Indicator | AC MODE | The 1st green LED lighting | ||||||
Battery MODE | The 2nd red LED flashing | |||||||
Fault | Red led lighting | |||||||
Audible Alarm | Battery Mode | Sounding everey 4 seconds | ||||||
Low battery | Sounding everey seconds | |||||||
Overload | ups off | |||||||
PROTECTION | Overload | As load over 130%, UPS is protected in 3 seconds | ||||||
AC input | Fuse for overload & short circuit protection | |||||||
Short circuit | UPS output cut off immediately | |||||||
Battery | Type | Sealed, lead acid maintenance-free | ||||||
protection | Auto-inspection, discharge protection and battery fault caution | |||||||
Battery | Normally battery is charged once every three months, it isn’ t less than 6 hours once a time. | |||||||
Physical | Weight(kg) | 4.75 | 6 | 6.5 | 7.5 | 8 | 11 | 12 |
Size (LxWxH)mm | 275*90*138 | 335*103*152 | 345x122x190 | |||||
Note: Product upgradation is a continuous process; hence specifications are subject to change without notice. |